Triton Alicante Electric Shower — White/Chrome | 8.5kW & 9.5kW

filler
Verkaufspreis£99 GBP
Aktie:
Auf Lager ( 14 Stück), versandbereit

Secure Payment Options:

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Triton Alicante Electric Shower — 8.5kW & 9.5kW

Great value, simple controls, and flexible installation. Triton Alicante is a popular like-for-like replacement with multiple left/right cable and water entry points for a tidy swap.

  • Easy replacement: multiple water & cable entry points on both sides
  • Simple controls: rotary power (Cold / Eco / High) & rotary temperature
  • 4-spray rub-clean handset with adjustable riser rail & 1.25 m anti-twist hose
  • Safety: low-pressure indicator & power-on light
  • Finish: White/Chrome

At-a-glance

  • Power options: 8.5kW or 9.5kW
  • Dimensions (H×W×D): 305 × 210 × 110 mm (approx.)
  • Water: Cold-mains only
  • Approvals: CE/UKCA; BEAB where applicable
  • Guarantee: 2 years (T&Cs apply)

Which power should I choose?

Model Typical Min. Running Pressure / Flow* Suggested Cable / MCB** Best for
8.5kW ≈ 1.0 bar @ 8 l/min Commonly 6–10 mm² / 40A (check site) Good performance on average mains
9.5kW ≈ 1.0 bar @ 9 l/min Often 10 mm² / 45–50A (verify) Hotter showers where supply allows

* Actual pressure/flow requirements depend on site conditions; always follow the Triton manual.
** Cable size and protective device depend on run length, installation method & local regs. A qualified electrician must confirm suitability to BS 7671.

What’s in the box

  • Triton Alicante shower unit (8.5kW or 9.5kW)
  • Adjustable riser rail with bracket & soap dish
  • 4-spray rub-clean handset & 1.25 m anti-twist hose
  • Fixings pack & installation/user guide

Installation notes

  • Cold-mains feed only. Ensure adequate dynamic pressure and flow at the unit.
  • Electrical connection by a competent person. Confirm cable size & MCB/RCBO rating before install.
  • Flush pipework before connection. Use isolating valves for service access.

FAQs

Will 9.5kW work on my existing cable?
It depends on your cable size, run length and installation method. Many 9.5kW installs require 10 mm² cable and a suitably rated MCB/RCBO. Ask a qualified electrician to confirm to BS 7671.
Is Alicante a good like-for-like replacement?
Yes — it offers multiple left/right water and cable entries, making it a strong candidate for swaps with minimal re-routing.
What maintenance is needed?
Periodically rub-clean the handset nozzles to prevent limescale and check the hose/rail fittings. Follow the user guide for cleaning.

Tip: If you’re upgrading from 8.5kW to 9.5kW, confirm that your water supply, cable size and protective device meet the higher demand before ordering.

Empfohlen für Sie

Customer Reviews

Based on 2 reviews Write a review