Grant Euroflame HE External Module Oil Boiler 50-90 15-26kW with Burner

filler
Verkaufspreis£1,520 GBP
Aktie:
Auf Lager ( 42 Stück), versandbereit

Secure Payment Options:

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Grant Euroflame HE External Module Oil Boiler 50-90 15-26kW with Burner

The Grant Euroflame HE Module Boiler External 50-90 is a high-efficiency, free-standing external oil-fired condensing boiler designed for domestic heating installations where internal boiler space is limited. With an output range of 15-26kW, this outdoor module is suitable for many small to medium-sized homes requiring reliable central heating from a kerosene oil boiler.

This model is supplied complete with burner and features a factory-fitted Riello RDB2.2 burner, helping deliver dependable combustion performance and efficient operation. The Euroflame external module range incorporates a version of Grant’s Vortex stainless steel heat exchanger and achieves an A energy rating, making it a strong choice for efficient oil boiler replacement projects.

Designed for outdoor installation, the weather-resistant external casing allows the boiler to be sited outside the property, helping free up internal space while maintaining straightforward service access for engineers. The unit also includes a factory-fitted multi-directional flue, with optional side or rear flue exits for flexible installation.

Key Product Information

  • Brand: Grant Engineering
  • Range: Euroflame HE / Euroflame Outdoor Condensing
  • Model: Euroflame External Module 50-90 / Outdoor 15-26
  • Manufacturer Part Number: EFCON5090MOD
  • Product Type: External oil-fired condensing boiler
  • Fuel Type: Kerosene
  • Output Range: 15-26kW
  • Burner: Riello RDB2.2
  • Energy Rating: A Rated
  • Installation Type: Free-standing external / outdoor module

Key Features and Benefits

  • Grant Euroflame HE external oil boiler supplied complete with burner
  • Output range of 15-26kW, suitable for many small to medium domestic properties
  • Manufacturer product code: EFCON5090MOD
  • Factory-fitted Riello RDB2.2 burner
  • High-efficiency condensing oil boiler design
  • Incorporates Grant Vortex stainless steel heat exchanger technology
  • A-rated heating efficiency
  • Designed for outdoor installation where internal space is limited
  • Free-standing external module with weather-resistant casing
  • Factory-fitted multi-directional flue
  • Optional side or rear flue exits for installation flexibility
  • Multiple flueing options available
  • Optional pipe entry points for easier installation
  • 22mm flow and return tappings
  • OFTEC and EC directive approved, according to manufacturer product information
  • 1-year manufacturer warranty with 5-year heat exchanger guarantee, subject to terms and conditions

Typical Applications

  • External oil boiler replacement projects
  • Homes without suitable internal boiler space
  • Small to medium domestic properties
  • Kerosene oil-fired central heating systems
  • Outdoor boiler installations
  • Heating upgrades requiring an efficient condensing oil boiler
  • Properties requiring flexible side or rear flue exit options

Product Specification

Brand Grant Engineering
Range Euroflame HE / Euroflame Outdoor Condensing
Model Euroflame External Module 50-90 / Outdoor 15-26
Manufacturer Part Number EFCON5090MOD
Product Type External oil-fired condensing boiler
Fuel Type Kerosene
Output Range 15-26kW
Set Output 23.5kW
Maximum Output 26kW
Burner Riello RDB2.2
Heat Exchanger Grant Vortex stainless steel heat exchanger design
Efficiency 92.4%
Energy Rating A Rated
NOx Emissions Compliant
Flow / Return Tappings 22mm
Flue Factory-fitted multi-directional flue
Flue Exit Options Optional side or rear flue exits
Installation Type Free-standing external / outdoor module
Height 908mm
Width 800mm
Depth 505mm
Weight 113kg
Warranty 1 year manufacturer's warranty with 5 year heat exchanger guarantee, subject to terms and conditions

What Is an External Module Oil Boiler?

An external module oil boiler is designed to be installed outside the home rather than in a kitchen, utility room or boiler house. This makes it ideal for properties where indoor space is limited, where noise reduction inside the home is preferred, or where an outdoor replacement boiler is the most practical installation option.

The Grant Euroflame HE 50-90 external module provides central heating through a conventional oil-fired boiler system. It is suitable for use with compatible heating controls, hot water cylinders and system components, depending on the overall heating design.

Flue and Installation Flexibility

This model is supplied with a factory-fitted multi-directional flue arrangement and supports optional side or rear flue exits. This helps installers adapt the flue route to suit property layout and site conditions, subject to the boiler installation manual and current oil boiler regulations.

Multiple flueing options and pipe entry choices make this outdoor module suitable for a wide range of replacement and new installation scenarios.

Why Choose the Grant Euroflame HE 50-90 External Module?

The Grant Euroflame HE External 50-90 combines efficient condensing performance with a practical outdoor casing. It is a strong option where a homeowner wants to free up internal space while retaining the performance of a high-efficiency Grant oil boiler.

Its stainless steel heat exchanger design, Riello burner, A energy rating and external weather-resistant format make it suitable for professional oil boiler installations where durability, serviceability and flexible siting are important.

Before Ordering

Please check the required boiler output, heating load calculation, existing fuel type, flue route, oil line requirements and installation location before ordering. Product suitability should be confirmed by an OFTEC registered oil heating engineer or suitably qualified heating professional.

  • Confirm the required output range is 15-26kW
  • Confirm the required model / product code is EFCON5090MOD
  • Check available external installation space
  • Check required flue direction and clearances
  • Check oil supply pipework and fire valve requirements
  • Check system design, controls, cylinder and pump requirements
  • Confirm delivery access due to the boiler weight and size

Important Installation Notice

Oil-fired boilers must be installed, commissioned and serviced by a suitably qualified oil heating engineer, ideally OFTEC registered. Installation must follow the Grant installation manual, building regulations, oil storage regulations and all relevant safety requirements.

Delivery Note

This is a large and heavy external boiler unit weighing approximately 113kg. Delivery may require pallet transport and suitable access for kerbside delivery. Please ensure lifting equipment or sufficient assistance is available on site before installation.