{"product_id":"boiler-m8-150-901-programmable-wired-thermostat","title":"Boiler-M8 150-901 Programmable Wired Thermostat - 7 Day 2 Wire Boiler Control","description":"\u003ch2\u003eBoiler-M8 150-901 Programmable Wired Thermostat\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBoiler-M8 150-901 Programmable Wired Thermostat\u003c\/strong\u003e is a versatile battery-powered room thermostat designed for accurate and convenient control of compatible domestic and light-commercial heating systems.\u003c\/p\u003e\n\u003cp\u003eIdeal for both new installations and thermostat upgrades, the 150-901 connects directly to the heating appliance using a \u003cstrong\u003evoltage-free COM \/ NO wired connection\u003c\/strong\u003e, making it suitable for many gas boilers, oil boilers, heat pumps, heating pumps, actuators and control systems that accept conventional on\/off thermostat switching.\u003c\/p\u003e\n\u003cp\u003eThe thermostat combines flexible \u003cstrong\u003e7-day programming\u003c\/strong\u003e with advanced \u003cstrong\u003eTPI or adjustable hysteresis temperature control\u003c\/strong\u003e, up to six programmable temperature periods per day, frost protection, holiday mode, temporary override and PIN locking.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler-M8 programmable wired room thermostat\u003c\/li\u003e\n\u003cli\u003eModel \/ part number: \u003cstrong\u003e150-901\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBattery-powered thermostat\u003c\/li\u003e\n\u003cli\u003eDirect wired connection to compatible heating appliance\u003c\/li\u003e\n\u003cli\u003eVoltage-free \u003cstrong\u003eCOM \/ NO relay output\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum relay load: \u003cstrong\u003e5(3)A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature range: \u003cstrong\u003e5°C to 35°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e7-day programmable heating control\u003c\/li\u003e\n\u003cli\u003eTwo different scheduling methods\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e6 programmable time and temperature periods per day\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgramming in intervals as precise as 10 minutes\u003c\/li\u003e\n\u003cli\u003eTPI temperature-control algorithm\u003c\/li\u003e\n\u003cli\u003eAdjustable hysteresis: ±0.25°C or ±0.5°C\u003c\/li\u003e\n\u003cli\u003eHeating and cooling operating modes\u003c\/li\u003e\n\u003cli\u003eComfort and economy temperature modes\u003c\/li\u003e\n\u003cli\u003eManual \/ temporary temperature override\u003c\/li\u003e\n\u003cli\u003eFrost protection mode\u003c\/li\u003e\n\u003cli\u003eHoliday mode\u003c\/li\u003e\n\u003cli\u003eParty mode\u003c\/li\u003e\n\u003cli\u003eMinimum and maximum temperature limits\u003c\/li\u003e\n\u003cli\u003eKey lock and PIN protection\u003c\/li\u003e\n\u003cli\u003eClear digital LCD display\u003c\/li\u003e\n\u003cli\u003eSliding programming panel\u003c\/li\u003e\n\u003cli\u003eTouch-sensitive control buttons\u003c\/li\u003e\n\u003cli\u003eSurface-mounted installation\u003c\/li\u003e\n\u003cli\u003eSuitable for many 2-wire thermostat replacement applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Boiler-M8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 150-901\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Programmable Wired Room Thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Type:\u003c\/strong\u003e Wired Programmable Thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Relay Load:\u003c\/strong\u003e 5(3)A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e Voltage-Free COM \/ NO Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Setpoint Range:\u003c\/strong\u003e 5°C - 35°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Temperature Resolution:\u003c\/strong\u003e 0.1°C or 0.5°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Algorithms:\u003c\/strong\u003e TPI or Hysteresis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis Settings:\u003c\/strong\u003e ±0.25°C \/ ±0.5°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Wired\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Daily \/ Weekly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Programmable Periods:\u003c\/strong\u003e 6 Per Day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchedule Resolution:\u003c\/strong\u003e Up to 10 Minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Modes:\u003c\/strong\u003e Heating \/ Cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 150mm x 84mm x 22mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface Mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e7-Day Programmable Heating Control\u003c\/h3\u003e\n\u003cp\u003eThe Boiler-M8 150-901 allows the heating system to automatically follow a programmed temperature schedule rather than maintaining one fixed room temperature throughout the day.\u003c\/p\u003e\n\u003cp\u003eThis allows the user to reduce the target temperature while sleeping or away from home and automatically increase it again when greater comfort is required.\u003c\/p\u003e\n\u003ch3\u003eTwo Different Scheduling Options\u003c\/h3\u003e\n\u003cp\u003eThe thermostat provides two different approaches to weekly programming.\u003c\/p\u003e\n\u003ch4\u003eSchedule Type 1 - Comfort \u0026amp; Economy\u003c\/h4\u003e\n\u003cp\u003eThe first programming method works around two user-selected temperatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort Temperature\u003c\/strong\u003e - normally used when the property is occupied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomy Temperature\u003c\/strong\u003e - normally used overnight or during periods of reduced demand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe thermostat's 24-hour timeline can then be programmed to automatically switch between the Comfort and Economy temperatures.\u003c\/p\u003e\n\u003cp\u003eSchedules can be configured as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonday-Friday plus separate Saturday-Sunday schedule\u003c\/li\u003e\n\u003cli\u003eIndividual schedule for each day\u003c\/li\u003e\n\u003cli\u003eOne identical schedule for all seven days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSchedule Type 2 - Up to 6 Temperature Periods Per Day\u003c\/h4\u003e\n\u003cp\u003eFor more detailed heating control, the second scheduling mode allows up to \u003cstrong\u003esix individual time and temperature periods per day\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEach period can have its own target temperature, with programme changes set in increments as precise as \u003cstrong\u003e10 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor example:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e06:00 - 21°C\u003c\/li\u003e\n\u003cli\u003e08:00 - 16°C\u003c\/li\u003e\n\u003cli\u003e11:00 - 19°C\u003c\/li\u003e\n\u003cli\u003e13:00 - 17°C\u003c\/li\u003e\n\u003cli\u003e16:00 - 21°C\u003c\/li\u003e\n\u003cli\u003e22:30 - 16°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis gives homeowners much greater flexibility to match heating operation to their daily routine.\u003c\/p\u003e\n\u003ch3\u003eTPI Temperature Control\u003c\/h3\u003e\n\u003cp\u003eThe Boiler-M8 150-901 supports \u003cstrong\u003eTPI - Time Proportional Integral - temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eRather than operating purely as a basic mechanical on\/off thermostat, TPI control manages heating cycles as the room approaches its desired temperature.\u003c\/p\u003e\n\u003cp\u003eThis can help maintain a more stable room temperature and reduce unnecessary temperature overshoot when correctly configured for the heating system.\u003c\/p\u003e\n\u003ch3\u003eAdjustable Hysteresis\u003c\/h3\u003e\n\u003cp\u003eWhere conventional on\/off temperature control is preferred, the thermostat can instead operate using adjustable hysteresis.\u003c\/p\u003e\n\u003cp\u003eAvailable settings include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±0.25°C\u003c\/li\u003e\n\u003cli\u003e±0.5°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis gives installers flexibility when matching thermostat behaviour to different heating systems.\u003c\/p\u003e\n\u003ch3\u003eVolt-Free Wired Boiler Connection\u003c\/h3\u003e\n\u003cp\u003eThe thermostat provides a \u003cstrong\u003evoltage-free COM \/ NO relay output\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis makes it suitable for many heating appliances that use conventional volt-free thermostat contacts, including selected:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas boilers\u003c\/li\u003e\n\u003cli\u003eCombination boilers\u003c\/li\u003e\n\u003cli\u003eSystem boilers\u003c\/li\u003e\n\u003cli\u003eRegular boilers\u003c\/li\u003e\n\u003cli\u003eOil boilers\u003c\/li\u003e\n\u003cli\u003eHeat pumps\u003c\/li\u003e\n\u003cli\u003eHeating pumps\u003c\/li\u003e\n\u003cli\u003eZone valves and actuators\u003c\/li\u003e\n\u003cli\u003eHeating wiring centres\u003c\/li\u003e\n\u003cli\u003eSelected cooling equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlways check the appliance manufacturer's control and wiring requirements before installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIdeal 2-Wire Thermostat Upgrade\u003c\/h3\u003e\n\u003cp\u003eBecause the Boiler-M8 150-901 is powered by \u003cstrong\u003e2 x AA batteries\u003c\/strong\u003e and uses a wired volt-free switching connection, it is particularly useful when upgrading many older battery-powered two-wire room thermostats.\u003c\/p\u003e\n\u003cp\u003eThe thermostat itself does not require a separate 230V mains supply.\u003c\/p\u003e\n\u003cp\u003eThis can help simplify replacement installations where existing thermostat cabling is already in place.\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Modes\u003c\/h3\u003e\n\u003cp\u003eThe thermostat can be configured for either \u003cstrong\u003eheating or cooling control\u003c\/strong\u003e, extending its use beyond standard domestic boiler installations.\u003c\/p\u003e\n\u003ch3\u003eManual Temperature Override\u003c\/h3\u003e\n\u003cp\u003eIf a temporary temperature change is required while the thermostat is following its automatic schedule, the user can adjust the required temperature manually.\u003c\/p\u003e\n\u003cp\u003eThe thermostat maintains the temporary temperature until the next scheduled programme change, after which normal automatic operation resumes.\u003c\/p\u003e\n\u003ch3\u003eComfort Mode\u003c\/h3\u003e\n\u003cp\u003eComfort mode allows the thermostat to maintain a constant user-defined daytime temperature.\u003c\/p\u003e\n\u003cp\u003eThis can be useful when the normal programme is not required but a comfortable fixed room temperature is still desired.\u003c\/p\u003e\n\u003ch3\u003eEconomy Mode\u003c\/h3\u003e\n\u003cp\u003eEconomy mode maintains a reduced temperature and can be useful overnight or while the property is unoccupied.\u003c\/p\u003e\n\u003cp\u003eThis provides a simple method of reducing heating demand without completely switching the heating system off.\u003c\/p\u003e\n\u003ch3\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe thermostat includes a dedicated frost-protection programme.\u003c\/p\u003e\n\u003cp\u003eWhen activated, the thermostat maintains approximately \u003cstrong\u003e7°C\u003c\/strong\u003e to help protect the property and heating system from freezing during prolonged periods of low temperature.\u003c\/p\u003e\n\u003ch3\u003eHoliday Mode\u003c\/h3\u003e\n\u003cp\u003eHoliday mode allows a reduced target temperature to be maintained for a user-selected number of days.\u003c\/p\u003e\n\u003cp\u003eOnce the holiday period has ended, the thermostat can return to its previous operating programme.\u003c\/p\u003e\n\u003ch3\u003eParty Mode\u003c\/h3\u003e\n\u003cp\u003eParty mode allows the Comfort temperature to temporarily override the normal heating schedule for a selected period.\u003c\/p\u003e\n\u003cp\u003eThe underlying thermostat platform supports a party-mode duration of up to approximately \u003cstrong\u003e9 hours\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eMinimum \u0026amp; Maximum Temperature Limits\u003c\/h3\u003e\n\u003cp\u003eInstaller settings allow the permitted thermostat temperature range to be restricted.\u003c\/p\u003e\n\u003cp\u003eThis can be particularly useful in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRental properties\u003c\/li\u003e\n\u003cli\u003eHoliday accommodation\u003c\/li\u003e\n\u003cli\u003eOffices\u003c\/li\u003e\n\u003cli\u003eCommercial premises\u003c\/li\u003e\n\u003cli\u003eCommunal areas\u003c\/li\u003e\n\u003cli\u003eProperties where excessive thermostat settings need to be prevented\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePIN \u0026amp; Key Lock\u003c\/h3\u003e\n\u003cp\u003eThe thermostat can be locked to help prevent accidental or unauthorised adjustment.\u003c\/p\u003e\n\u003cp\u003eA PIN protection option is also available for installations where greater control over user access is required.\u003c\/p\u003e\n\u003ch3\u003eClear LCD Display\u003c\/h3\u003e\n\u003cp\u003eThe front display provides clear information including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent room temperature\u003c\/li\u003e\n\u003cli\u003eRequired temperature\u003c\/li\u003e\n\u003cli\u003eCurrent time\u003c\/li\u003e\n\u003cli\u003eDay of the week\u003c\/li\u003e\n\u003cli\u003eHeating or cooling demand\u003c\/li\u003e\n\u003cli\u003eComfort \/ economy status\u003c\/li\u003e\n\u003cli\u003eFrost protection\u003c\/li\u003e\n\u003cli\u003eHoliday mode\u003c\/li\u003e\n\u003cli\u003eProgramme information\u003c\/li\u003e\n\u003cli\u003eLow battery indication\u003c\/li\u003e\n\u003cli\u003eKey lock status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSliding Programming Panel\u003c\/h3\u003e\n\u003cp\u003eThe thermostat uses a sliding front control panel which keeps the main appearance simple during normal operation while providing access to additional programming controls when required.\u003c\/p\u003e\n\u003ch3\u003eCompact Wall-Mounted Design\u003c\/h3\u003e\n\u003cp\u003eThe Boiler-M8 150-901 measures approximately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 150mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 84mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 22mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts slim surface-mounted design makes it suitable for both replacement and new heating-control installations.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas boiler heating control\u003c\/li\u003e\n\u003cli\u003eOil boiler heating control\u003c\/li\u003e\n\u003cli\u003eCombination boiler control\u003c\/li\u003e\n\u003cli\u003eSystem boiler control\u003c\/li\u003e\n\u003cli\u003eRegular boiler control\u003c\/li\u003e\n\u003cli\u003eHeat pump control where volt-free switching is supported\u003c\/li\u003e\n\u003cli\u003eReplacing older wired thermostats\u003c\/li\u003e\n\u003cli\u003eDomestic central heating\u003c\/li\u003e\n\u003cli\u003eRental properties\u003c\/li\u003e\n\u003cli\u003eHoliday accommodation\u003c\/li\u003e\n\u003cli\u003eOffices\u003c\/li\u003e\n\u003cli\u003eLight-commercial heating systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's Included?\u003c\/h3\u003e\n\u003cp\u003eThe underlying thermostat platform is normally supplied with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Programmable Wired Thermostat\u003c\/li\u003e\n\u003cli\u003e2 x AA Batteries\u003c\/li\u003e\n\u003cli\u003eMounting Screws\u003c\/li\u003e\n\u003cli\u003eInstallation \/ User Instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm the final Boiler-M8 retail packaging contents before publishing individual accessories as included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Compatibility Information\u003c\/h3\u003e\n\u003cp\u003eThe Boiler-M8 150-901 is designed for heating systems using conventional wired on\/off thermostat control.\u003c\/p\u003e\n\u003cp\u003eIt should \u003cstrong\u003enot be assumed to be compatible with every boiler\u003c\/strong\u003e. Some modern appliances use manufacturer-specific digital, bus or modulating control protocols rather than standard COM \/ NO thermostat switching.\u003c\/p\u003e\n\u003cp\u003eBefore installation, always confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler thermostat connection type\u003c\/li\u003e\n\u003cli\u003eRequired switching voltage\u003c\/li\u003e\n\u003cli\u003eElectrical load\u003c\/li\u003e\n\u003cli\u003eExisting thermostat wiring\u003c\/li\u003e\n\u003cli\u003eBoiler manufacturer wiring instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional Installation Recommended\u003c\/h3\u003e\n\u003cp\u003eInstallation involves electrical wiring to the heating appliance or heating-control circuit and should be undertaken by a suitably competent heating or electrical professional.\u003c\/p\u003e\n\u003cp\u003eWhere installation requires removal of a gas boiler casing or access to components covered by gas-safety legislation, the work must be completed by a suitably qualified \u003cstrong\u003eGas Safe registered engineer\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Boiler M8","offers":[{"title":"Default Title","offer_id":51104576864512,"sku":"BOILERM8-150-901","price":32.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/2814\/files\/Boiler_M8_901_wired2_png.png?v=1795012336","url":"https:\/\/spares-direct.com\/es\/products\/boiler-m8-150-901-programmable-wired-thermostat","provider":"Spares Direct","version":"1.0","type":"link"}