Ideal 177358 Sump and Cover Replacement Kit for Logic Heat Boilers

filler
Prix réduit£65 GBP
Stock:
Plus que 6 en stock

Secure Payment Options:

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Ideal 177358 Sump and Cover Replacement Kit

The Ideal 177358 Sump and Cover Replacement Kit is a genuine Ideal Heating boiler spare designed for selected Ideal Logic Heat, Logic+ Heat and Logic Max Heat boilers. This replacement kit is used within the boiler sump / condensate area and is supplied with the key sealing components required for a secure replacement.

The sump and cover assembly helps manage condensate and discharge produced during normal condensing boiler operation. Condensate is mildly acidic, so a correctly sealed sump cover is essential for preventing leaks, protecting nearby components and maintaining safe boiler performance.

This kit is commonly replaced during boiler servicing or repair when the existing sump cover is cracked, leaking, worn, damaged or no longer sealing correctly. It is suitable for professional repair work on compatible Ideal heat-only boiler models.

Key Product Information

  • Brand: Ideal Heating
  • Manufacturer Part Number: 177358
  • GTIN / Barcode: 5022141773587
  • Product Type: Sump and Cover Replacement Kit
  • Compatible Boiler Type: Selected Ideal heat-only boilers
  • Application: Boiler sump and condensate discharge management
  • Condition: New replacement boiler spare

Key Features and Benefits

  • Genuine Ideal Heating replacement part
  • Designed for selected Ideal Logic Heat, Logic+ Heat and Logic Max Heat boilers
  • Helps restore a secure seal around the boiler sump assembly
  • Used to manage condensate and acidic discharge within the appliance
  • Supplied with O-ring and screw for replacement fitting
  • Helps prevent leaking or weeping from the sump cover area
  • Suitable for boiler servicing, maintenance and repair work
  • Ideal replacement for cracked, damaged, worn or leaking sump covers
  • OEM boiler spare for reliable compatibility and fitment

What’s Included?

  • Ideal sump cover
  • O-ring seal
  • Fixing screw

Compatible Boiler Ranges

This Ideal sump and cover replacement kit is designed for selected Ideal heat-only boiler models. Always check the boiler data badge, GC number, appliance serial number and manufacturer parts diagram before ordering.

  • Ideal Logic Heat boilers
  • Ideal Logic+ Heat boilers
  • Ideal Logic Max Heat boilers
  • Selected Ideal Heat H models
  • Selected Ideal heat-only boilers using part number 177358

Example Compatible Models

  • Ideal Logic Heat 12
  • Ideal Logic Heat 15
  • Ideal Logic Heat 18
  • Ideal Logic Heat 24
  • Ideal Logic Heat 30
  • Ideal Logic Heat H12
  • Ideal Logic Heat H15
  • Ideal Logic Heat H18
  • Ideal Logic Heat H24
  • Ideal Logic Heat H30
  • Ideal Logic Heat 2 H12
  • Ideal Logic Heat 2 H15
  • Ideal Logic Heat 2 H18
  • Ideal Logic Heat 2 H24
  • Ideal Logic Heat 2 H30
  • Ideal Max Heat H12
  • Ideal Max Heat H15
  • Ideal Max Heat H18
  • Ideal Max Heat H24
  • Ideal Max Heat H30

Product Specification

Brand Ideal Heating
Product Name Ideal Sump and Cover Replacement Kit
Manufacturer Part Number 177358
GTIN / Barcode 5022141773587
Product Type Boiler sump and cover replacement kit
Kit Contents Sump cover, O-ring and screw
Application Condensate sump sealing and discharge management
Compatible Boiler Type Selected Ideal heat-only boilers
Compatible Ranges Ideal Logic Heat, Logic+ Heat and Logic Max Heat models
Condition New replacement boiler spare
Approximate Weight 0.3kg placeholder — confirm against packaging or supplier data

What Does the Boiler Sump and Cover Do?

In a condensing boiler, condensate is produced as part of the high-efficiency combustion process. This condensate must be safely collected and routed through the boiler’s condensate system. The sump and cover assembly helps contain and manage this discharge before it exits through the condensate pipework.

If the sump cover or seal becomes damaged, water or condensate can leak from the appliance. Because condensate is mildly acidic, leaks should be addressed quickly to help protect internal boiler parts and surrounding surfaces.

Common Reasons for Replacement

  • Leaking or weeping from the sump cover area
  • Cracked or damaged plastic cover
  • Perished, flattened or failed O-ring seal
  • Visible staining or residue around the sump assembly
  • Condensate leak identified during annual service
  • Boiler engineer diagnosis requiring sump cover replacement
  • Preventative replacement during repair work where the seal has been disturbed

Installation Guidance

This part should be installed by a competent heating professional. The boiler must be isolated and made safe before any internal components are removed. After fitting, the sump assembly should be checked for correct seating, secure fastening and watertight sealing.

Once installed, the boiler should be tested for correct operation and inspected for leaks around the sump, condensate trap and discharge path.

Important Safety Notice

Gas boiler spares should only be fitted by a Gas Safe registered engineer or suitably qualified heating professional. Always refer to the manufacturer’s installation and servicing instructions before replacing internal boiler components.

Before Ordering

Please confirm compatibility before purchase. Boiler parts can vary depending on production date, appliance version and GC number.

  • Check the boiler model name
  • Check the GC number on the appliance data badge
  • Check the appliance serial number
  • Compare the existing part with the manufacturer exploded diagram
  • Confirm the required part number is 177358

Why Buy This Ideal 177358 Kit?

Choosing a genuine Ideal sump and cover replacement kit helps ensure the correct fit, seal and material compatibility for supported Ideal boiler models. This makes it a reliable choice for professional boiler repairs and servicing where condensate sealing is critical.

For best results, the replacement should be fitted as part of a full inspection of the condensate system, including the sump, trap, seals and condensate discharge pipework.