Glow-worm 0020097328 Expansion Vessel - Betacom, Easicom, Energy & Ultracom 2

filler
Verkaufspreis£82 GBP
Aktie:
Nur noch 10 Einheiten übrig.

Secure Payment Options:

American Express Apple Pay Diners Club Discover Google Pay Maestro Mastercard PayPal Shop Pay Union Pay Visa

Glow-worm 0020097328 Expansion Vessel

The Glow-worm 0020097328 Expansion Vessel is a genuine replacement boiler expansion vessel designed for a wide range of Glow-worm heating appliances.

Used within the sealed central-heating circuit, the expansion vessel accommodates the increase in water volume that occurs as the heating system warms up, helping maintain stable system pressure and preventing excessive pressure increases.

Glow-worm part number 0020097328 is fitted across numerous Betacom, Easicom, Energy, Essential, Home, Sustain, Ultimate and Ultracom 2 boiler models.

Key Features

  • Genuine Glow-worm replacement expansion vessel
  • Manufacturer part number: 0020097328
  • EAN / GTIN: 5037985082351
  • Direct replacement where 0020097328 is specified
  • Designed for sealed central-heating systems
  • Absorbs expansion of heating water as system temperature rises
  • Helps maintain stable boiler and system pressure
  • Reduces excessive pressure increases during heating operation
  • Flat rectangular steel vessel design
  • Suitable for a very wide range of Glow-worm boilers
  • Used across combi and system boiler applications

Product Specification

  • Brand: Glow-worm
  • Product Type: Boiler Expansion Vessel
  • Manufacturer Part Number: 0020097328
  • EAN / GTIN: 5037985082351
  • Application: Sealed Central Heating Circuit
  • Construction: Flat Rectangular Metal Expansion Vessel
  • Function: Heating System Pressure Compensation
  • Condition: New
  • OEM Status: Genuine Glow-worm when supplied in manufacturer packaging

Expansion Vessel Capacity

Glow-worm 0020097328 is commonly catalogued by major UK heating merchants as a 10 litre expansion vessel.

Some current boiler-spares databases alternatively describe the same manufacturer part number as an 8 litre vessel. For this reason, if capacity is critical for your application, confirm the specification shown on the label of the supplied vessel or against the appliance manufacturer's technical information.

What Does an Expansion Vessel Do?

Water expands as it is heated. In a sealed central-heating system there needs to be somewhere for this additional volume to go without causing the system pressure to rise excessively.

The expansion vessel contains a flexible internal diaphragm separating the heating water from a pressurised air or gas chamber.

As the heating water expands, it pushes against the diaphragm and compresses the air side of the vessel. This helps keep system pressure within the intended operating range.

Possible Symptoms of Expansion Vessel Failure

A failed, discharged or damaged expansion vessel may contribute to symptoms including:

  • Boiler pressure rising significantly when the heating is switched on
  • Pressure dropping again when the system cools
  • Frequent requirement to repressurise the heating system
  • Pressure relief valve discharging water
  • System pressure approaching or exceeding 3 bar
  • Water escaping through the pressure relief discharge pipe
  • Boiler pressure fluctuations between hot and cold operation

These symptoms may also be caused by other heating-system faults. The appliance should therefore be professionally diagnosed before replacing the expansion vessel.

Compatible Glow-worm Boiler Ranges

Part number 0020097328 is listed across selected models within the following Glow-worm ranges:

  • Glow-worm Betacom
  • Glow-worm Betacom 2
  • Glow-worm Betacom 3
  • Glow-worm Betacom 4
  • Glow-worm Easicom
  • Glow-worm Easicom 2
  • Glow-worm Easicom 3
  • Glow-worm Energy
  • Glow-worm Essential
  • Glow-worm Home
  • Glow-worm Sustain
  • Glow-worm Ultimate
  • Glow-worm Ultimate 2
  • Glow-worm Ultimate 3
  • Glow-worm Ultracom 2

Example Compatible Models

  • Betacom 2 24
  • Betacom 2 28
  • Betacom 24A
  • Betacom 28A
  • Betacom 3 24C
  • Betacom 3 30C
  • Betacom 4 24C
  • Betacom 4 30C
  • Easicom 24
  • Easicom 28
  • Easicom 2 24C
  • Easicom 2 28C
  • Easicom 3 24C
  • Easicom 3 25S
  • Easicom 3 28C
  • Energy 12S
  • Energy 15S
  • Energy 18S
  • Energy 25C
  • Energy 25S
  • Energy 30C
  • Energy 30S
  • Energy 35C
  • Essential 24C
  • Essential 28C
  • Home 12S
  • Home 15S
  • Home 18S
  • Home 25C
  • Home 25S
  • Home 30C
  • Home 35C
  • Sustain 12S
  • Sustain 15S
  • Sustain 18S
  • Sustain 25C
  • Sustain 30C
  • Sustain 35C
  • Ultimate 2 25S
  • Ultimate 2 30C
  • Ultimate 2 35C
  • Ultimate 3 25S
  • Ultimate 3 30C
  • Ultimate 3 35C
  • Ultracom 2 12SXi
  • Ultracom 2 18SXi
  • Ultracom 2 24CXi
  • Ultracom 2 30CXi
  • Ultracom 2 30SXi
  • Ultracom 2 35CXi

Example Gas Council Numbers

  • Betacom 2 24: 47-019-16
  • Betacom 2 28: 47-019-17
  • Betacom 24A: 47-019-13
  • Betacom 28A: 47-019-14
  • Betacom 3 24C: 47-019-41
  • Betacom 3 30C: 47-019-42
  • Easicom 2 24C: 47-019-22
  • Easicom 2 28C: 47-019-23
  • Energy 25C: 47-019-24
  • Energy 30C: 47-019-25
  • Energy 35C: 47-019-26
  • Ultracom 2 24CXi: 47-019-10
  • Ultracom 2 30CXi: 47-019-11
  • Ultracom 2 35CXi: 47-019-12

Important Compatibility Information

Always confirm compatibility before ordering.

Glow-worm has produced many boiler variants and revisions. Components can vary depending on the exact appliance model, production date, Gas Council number and serial number.

The safest method is to confirm that manufacturer part number 0020097328 is specified for the appliance.

If you are unsure, provide the full boiler model, Gas Council number and serial number before ordering.

Professional Installation Recommended

Replacement of an internal boiler expansion vessel normally requires the heating circuit to be isolated and depressurised.

The replacement vessel must also be correctly installed and the heating system repressurised and tested afterwards.

Where access requires removal of the boiler's room-sealed combustion casing or other work covered by gas-safety legislation, the work must be carried out by a suitably qualified Gas Safe registered engineer.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Empfohlen für Sie