Boiler-M8 150-901RF Programmable Wireless Thermostat

The Boiler-M8 150-901RF Programmable Wireless Thermostat is a versatile wireless room thermostat designed to provide accurate, convenient temperature control for domestic and light-commercial heating systems.

Featuring a battery-powered programmable room thermostat and separate 230V wireless boiler receiver, the 150-901RF allows the thermostat to be positioned in a suitable living area without the need to run control wiring between the thermostat and boiler.

The system uses reliable 868MHz wireless communication and offers advanced temperature-control options including TPI control, adjustable hysteresis, daily and weekly programming, manual override and up to six programmable temperature periods per day.

Suitable for controlling compatible gas boilers, oil boilers, heat pumps, pumps, actuators and other heating or cooling equipment using a volt-free thermostat connection.

Key Features

  • Boiler-M8 programmable wireless room thermostat
  • Model / part number: 150-901RF
  • Wireless thermostat and separate boiler receiver
  • Weekly programmable temperature control
  • Two different scheduling methods
  • Up to 6 programmable temperature periods per day
  • Thermostat temperature range: 5°C to 35°C
  • TPI temperature-control algorithm
  • Adjustable hysteresis control: ±0.25°C or ±0.5°C
  • Wireless communication: 868MHz
  • Wireless range up to approximately 100 metres in open space
  • Voltage-free COM / NO relay output
  • Receiver maximum switching load: 16(5)A
  • Receiver supply: 230V AC 50Hz
  • Thermostat powered by 2 x AA alkaline batteries
  • Heating and cooling control modes
  • Manual temperature override
  • Comfort and economy temperature modes
  • Minimum and maximum temperature setpoint limiting
  • PIN / keypad locking function
  • Automatic wireless signal renewal
  • Clear LCD display
  • Sliding control panel for additional programming functions
  • Factory-paired thermostat and receiver system

Product Specification

  • Brand: Boiler-M8
  • Model: 150-901RF
  • Product Type: Programmable Wireless Room Thermostat
  • Control Type: Programmable RF Thermostat & Receiver
  • Thermostat Power Supply: 2 x AA Alkaline Batteries
  • Receiver Power Supply: 230V AC 50Hz
  • Receiver Maximum Load: 16(5)A
  • Receiver Output: Voltage-Free COM / NO Relay
  • Temperature Setpoint Range: 5°C - 35°C
  • Display Temperature Resolution: 0.1°C or 0.5°C
  • Control Algorithms: TPI or Hysteresis
  • Hysteresis Options: ±0.25°C / ±0.5°C
  • Wireless Frequency: 868MHz
  • Maximum RF Range: Up to 100m in open space
  • Programming: Daily / Weekly
  • Programmable Periods: Up to 6 per day using Schedule Type 2
  • Operating Modes: Automatic / Manual / Heating / Cooling
  • Thermostat Dimensions: 150mm x 84mm x 22mm
  • Receiver Dimensions: 96mm x 96mm x 27mm
  • Colour: White
  • Installation: Surface Mounted

Programmable Heating Control

The Boiler-M8 150-901RF allows users to automatically control their heating according to the time of day and required room temperature.

Rather than leaving the heating operating at one fixed temperature throughout the day, the thermostat can automatically increase or reduce the target temperature according to the programmed schedule.

This provides greater comfort while helping avoid unnecessary heating when higher room temperatures are not required.

Two Different Scheduling Options

The 150-901RF platform provides two programming methods, allowing the installer or homeowner to select the approach that best suits the property.

Schedule Type 1 - Comfort & Economy

The first scheduling method uses two predefined target temperatures:

  • Comfort Temperature - typically used while the property is occupied
  • Economy Temperature - typically used overnight or during periods of reduced heating demand

A 24-hour timeline can then be programmed to automatically switch between these temperatures.

Schedule Type 2 - Up to 6 Temperature Periods Per Day

For more detailed control, Schedule Type 2 allows up to six individual time and temperature periods per day.

For example:

  • 06:00 - 21°C
  • 08:00 - 16°C
  • 11:00 - 19°C
  • 13:00 - 17°C
  • 16:00 - 21°C
  • 22:30 - 16°C

This gives the user considerable flexibility to match heating operation to their daily routine.

Flexible Weekly Programming

Schedules can be configured in several ways:

  • Separate Monday-Friday and weekend schedules
  • Individual schedules for each day
  • One identical schedule for the entire week

This makes the thermostat suitable for households with both regular and varied working patterns.

TPI Temperature Control

The Boiler-M8 150-901RF supports TPI - Time Proportional Integral - control.

TPI control allows the thermostat to manage heating cycles more intelligently as the room approaches its required temperature rather than simply operating as a basic mechanical on/off thermostat.

Different TPI settings can be selected to better suit different heating applications.

Adjustable Hysteresis Control

For systems where conventional on/off temperature control is preferred, the thermostat can also operate using adjustable hysteresis.

Available settings include:

  • ±0.25°C
  • ±0.5°C

This gives installers greater flexibility when matching the thermostat to the behaviour of the heating system.

868MHz Wireless Communication

The thermostat communicates with the boiler receiver using a dedicated 868MHz RF wireless signal.

In open-space conditions the hardware platform is capable of wireless communication at distances of up to approximately 100 metres.

Actual installed range will depend on building construction, wall thickness, metalwork, electrical equipment and other sources of wireless interference.

Volt-Free Boiler Connection

The receiver provides a voltage-free COM / NO relay output, making the thermostat suitable for a wide range of compatible heating appliances that accept a standard volt-free room-thermostat connection.

Applications can include:

  • Gas boilers
  • Oil boilers
  • Combination boilers
  • System boilers
  • Heat pumps where compatible with volt-free control
  • Heating pumps
  • Zone valves and actuators
  • Heating control centres
  • Selected cooling equipment

Always verify the appliance control requirements before installation.

Battery Powered Room Thermostat

The room thermostat is powered by 2 x AA alkaline batteries, allowing it to communicate wirelessly with the receiver without requiring a 230V electrical supply at the thermostat position.

This can make installation particularly convenient when replacing older wired room thermostats or where running additional control cable through the property would be difficult.

230V Wireless Receiver

The separate receiver is powered from a 230V AC 50Hz supply and provides the switching connection to the boiler or heating appliance.

The receiver is rated to a maximum load of 16(5)A and incorporates manual controls allowing the connected heating appliance to be switched independently during commissioning or troubleshooting.

Manual Override

The user can temporarily adjust the required room temperature without completely reprogramming the heating schedule.

This is useful when a temporary increase or reduction in temperature is required outside the normal programmed routine.

Heating & Cooling Control

The 150-901RF hardware supports both heating and cooling operating modes, increasing the range of compatible temperature-control applications.

Temperature Setpoint Limits

Minimum and maximum temperature settings can be restricted within the installer menu.

This can be useful in:

  • Rental properties
  • Commercial premises
  • Offices
  • Holiday accommodation
  • Properties where excessive thermostat settings need to be prevented

PIN / Key Lock

The thermostat includes a locking function which can help prevent accidental or unauthorised adjustment of temperature and control settings.

This is particularly useful in rented properties, communal spaces and light-commercial installations.

Clear LCD Display

The thermostat features a clear digital LCD displaying information such as:

  • Current room temperature
  • Selected temperature
  • Current time
  • Heating demand
  • Operating mode
  • Program information
  • Schedule timeline where applicable

Compact Dimensions

The thermostat measures approximately:

  • Width: 150mm
  • Height: 84mm
  • Depth: 22mm

The wireless receiver measures approximately:

  • Width: 96mm
  • Height: 96mm
  • Depth: 27mm

What's Included?

The Boiler-M8 150-901RF thermostat set includes the core wireless control system:

  • 1 x Boiler-M8 Programmable Wireless Room Thermostat
  • 1 x Boiler-M8 Wireless Boiler Receiver

Depending on final Boiler-M8 packaging, batteries, mounting hardware and connection accessories may also be supplied. Please confirm the contents shown on the retail packaging before advertising individual accessories as included.

Ideal For

  • Boiler replacements
  • New heating installations
  • Replacing older mechanical thermostats
  • Replacing basic non-programmable thermostats
  • Gas boiler installations
  • Oil boiler installations
  • Heating upgrades
  • Landlords and rental properties
  • Domestic properties
  • Offices and light-commercial premises

Important Compatibility Information

The Boiler-M8 150-901RF uses a voltage-free relay output and is therefore compatible with many heating appliances, but it should not be assumed to be compatible with every boiler or heating system.

Some modern heating appliances use proprietary digital or modulating communication systems rather than conventional on/off thermostat contacts.

Always check the boiler or heating appliance manufacturer's wiring instructions before installation.

Professional Installation Recommended

The room thermostat itself is battery powered, but the wireless receiver requires a 230V electrical supply and connection to the heating appliance.

Installation should therefore be undertaken by a suitably competent heating or electrical professional.

Where installation involves opening or working within a gas boiler enclosure, the work must be carried out by a suitably qualified Gas Safe registered engineer.